What is IES TM-30-15?

What is IES TM-30-15?

Light Color

TM30-15
TM30-15

The Technical Memorandum, TM-30-15, the new method published by IES in 2015 and has been proposed to the CIE. This new color evaluation function is expected to provide the angle of technological innovation for light source measuring, furthermore, it can help users analyze the color characteristics of the modern and the traditional solid-state light source, and thus enhance the fairness and accuracy of the measurement.

TM-30-15 uses 99 samples
TM-30-15, which considers 99 real-world objects having a variety of colors - these were carefully chosen for their reflectance properties. (Based on 105,000 objects)
TM-30-15 Measurement Index
TM-30-15 including Color Vector Graphic, Color Fidelity Index (Rf) and Color Gamut Score (Rg)
◎ COLOR VECTOR GRAPHICS
Color vector graphics use visual description to tell us the changes of hue and saturation. The graph below tells us how various colors are distorted.
The above 3 lights are close to color temperature 3500K. If we use them on plant landscaping, and we expect to bring people a greenery feeling.
Red line: test source (Light A, B, C)
Black line: reference illuminant
For A light on the color Vector Graphic
Red circle on the green gamut is outside black circle; it means green color is over-saturation.
For B light on the color Vector Graphic
Red circle on the green gamut is inside the black circle; it means green color is under-saturation.
For C light on the color Vector Graphic
Red circle on the green gamut is overlap on black circle; it means green color is close to true color.
Users could accord TM-30-15 measure data to determine the effects of saturation and color of the light source.
◎ COLOR FIDELITY INDEX - Rf
Fidelity index Rf indicates whether a light source near to natural or not.
Rf = 100 (maximum), colors are most real as the "natural" color.
Rf = 0 (minimum), color shifts occur make seriously color aberration.
◎ COLOR GAMUT SCORE - Rg
Gamut index Rg indicates whether a light source over or under saturation.
Rg = 100, it means no average change in saturation.
Rg > 100, it means the saturation tends to be increased.
Rg < 100, it means the saturation tends to be decreased.
We hope you can get a basic knowledge from above information of TM-30-15. UPRtek also add this function into our product to let customers get the most updated technology. For more information, please check the relatived products below.
Related Products
  • Visual Merchandising, LED Lighting Solutions-Handheld Spectrometer - UPRtek MK350S Premium Spectrometer
    Visual Merchandising, LED Lighting Solutions-Handheld Spectrometer
    MK350S Premium

    MK350S Premium is a Handheld Spectrometer with Muli-Functions in itself. It's not only a Spectrometer, but also can be a Quantum PAR Meter, and Oscilloscope. Especially we add the BLH Judgement feature in it which's the latest popular topic and requirement for the Lighting industry. The strong and various functions can make users task quicker and efficiently.


  • Stand alone Spectral Light meter-Handheld Spectrometer - UPRtek MK350N_Premium Handheld Spectrometer
    Stand alone Spectral Light meter-Handheld Spectrometer
    MK350N Premium

    MK350N Premium is a Spectrum Analyzer, LED Meter and Flicker Meter for LED manufacture. Embedded with spectral technology and optimize the LUX measuring range. Overall, the measuring result becomes more accurate which can be your best reliable helper.


  • SPECTRAL COLOR METER - UPRtek CV600 Spectral Color Meter
    SPECTRAL COLOR METER
    CV600

    CV600 - All purpose Professional Cinematic and Photographic Light meter. It is not only a Light meter, but also a Color meter, Cine meter and Exposure meter a quicker, more efficient measurements for cinematographer, videographer, video makers, and film producers to capture every life moment!


  • Lighting measurement system-Handheld Spectrometer - UPRtek MK350S Handheld Spectrometer
    Lighting measurement system-Handheld Spectrometer
    MK350S Advanced

    Advanced MK350S the 1st handheld Spectrometer cross to muti-industrials. It had more than 40 light measurement units which are CCT, LUX, CRI, CIE1976, CIE1931,PPF, CQS, Duv, LambdaP, S/P ratio, TLCI, GAI... No matter for RD lighting designers, lighting manufactory and quality control, interior light designers, horticulture measurement, cinematographer and health prevention...and so on.MK350S is designed to meet the needs of all users.


  • LED Test & Measurement-Handheld Spectrometer - UPRtek MK350N PlusHandheld Spectrometer
    LED Test & Measurement-Handheld Spectrometer
    MK350N Plus

    MK350N PLUS is the LED meter for LED Manufacturer. It included more than 40 light measurement units such as CCT, CRI, CIE1931/1976, LUX, TLCI and others. Assist you to discover new business opportunities on innovation and green LED technology. It is a Spectrum Analyzer, LED Meter and Flicker Meter for LED manufacture.



Related FAQ
Let's have an over view of the 3 common types of artificial light. The traditional Incandescent bulbs were first on the scene. Next, came the Fluorescent Lights and then LED Lights, both bringing advantages in bulb lifespan and energy savings. However, they are all three, still in use with their own distinct advantages and disadvantages. Read More
Incandescent lighting uses heat (thermal radiation) to produce light. Sunlight and Candle light are generated in this way. Incandescent Light Bulbs also generate heat (thermal radiation) through a "filament". The filament heats up to produce light like a candle. Read More
Fluorescent Lights have been commercially available since the 1930s as long Fluorescent Tubes. A smaller bulb like CFL (Compact Fluorescent Light) only became widely available in the 2000s. These lights use a mercury vapor (steam) inside the tube; electricity is applied within the tube, which causes the mercury vapor to emit UV light, or more accurately UV radiation. The UV radiation hits the inside surface of the tube which is coated with a phosphor material. The UV radiation causes the phosphor to glow. Read More
Early LEDs (Light Emitting Diodes) were used mainly for small indicator lights for applications like display panels, they have been used in this way since the 1960s and they looked like the bulbs as below picture. Read More
Practically and economically speaking, LEDs seem to have a huge advantage and this is why most newly built facilities in developing countries are choosing LEDs for most of their environment lighting (e.g. factories, offices, libraries, museums). Read More
Understanding the basics of what light is and where light comes from is the key to understanding LED lighting and UPRtek handheld spectrometers. However, we must first get our feet wet in the world of Science, particularly Physics and Chemistry. Here explains the lighting fundamentals in layman terms, in a straightforward, concise and practical way, without any MATH! Read More
Inside an Incandescent bulb, electricity is used to heat up the Tungsten Filament. The electrons in the Tungsten Filament begin to jump out to a higher energy orbit for an instance and then drop back to its natural orbit, releasing light. (You can also refer “Making Light of Things” from the FAQ of Where does light come from? ) Read More
As we mentioned in artificial light FAQs, a Fluorescent Light makes light in two separate steps; electricity causes mercury vapor to emit UV light, the UV light strikes the Phosphor inner lining and causes the Phosphor to emit visible light. In both cases, the same mechanisms of Energy-Atom-Electron-Photon are in effect. Read More
As we saw on the previous FAQ“Where does light come from?”, electrons at higher orbits that drop back to lower orbits, release photons of light. In LED semiconductors, a similar strategy is at work. Electrons jump from higher energy states to lower energy states. Read More
Let us first explain that the color is come from light by Newton's experiment of simulating the phenomenon of rainbows; then, after the light enters the human eye, photoreceptor cells will receive and act on the light for colors from the object; at last, let’s explore what happened when the light hits on the object, through the dance of light - Reflection, Absorption and Transmission to have further understand the color. In addition, since the judgment of the color is not the same by each person, through UPRtek spectrometer to determine the color consistency, color rendering and saturation...etc. Let’s agree to disagree. Read More
The industries that care color performance are store display, architectural lighting design, cinema and film lighting, etc. If we assume that sunlight is the “gold standard” for color rendering or color quality, how do we rate a certain LED light? This is done with a measuring “stick” called CRI (color rendering index). A CRI of 100 represents natural color rendering quality (i.e. from sunlight, black body radiator, incandescent) - anything below that represents varying degrees in deficiency. For cinema lighting, CRI ratings for a light over 95 is considered excellent. It’s important to remember that CRI does not measure how true a color is, but measures the amount of that color in a light (sometimes referred to as the intensity or magnitude). Read More
The CQS(Color Quality Scale)is a new light source quality parameter developed by NIST (National Institute of Standards and Technology)for the new solid-state lighting markets. As we mentioned in the article on what is Color Rendering Index, since CRI proposed by the International Commission on Illumination caused some problems with the use of unsaturated colors and a small amount of sample colors. CQS is using higher saturation color, and proposed 15 new colors to evaluate the light source, the value of 100 represents the best quality of the light source, 0 represents the worst light source quality. Read More
An undesired change in visual perception induced by a light stimulus whose luminance or spectral distribution fluctuates with time, for an observer in a certain environment. Read More
This article compares three flicker metrics regarding percent flicker, flicker index and SVM. The comparison includes the definition comes from which organization, the definition of itself, calculation formula and the description of the range. If you want to know more about which products have related measurement functions, please click on the relative products tab. Read More
Cosine is a mathematical function used to calculate and specify the characteristics (length & angles) of triangles (Trigonometry). Below right picture is the cosine correction comparison between MK350S Premium and Lambert’s Cosine Law. The ideal value of the red circle was described by Johann Hein¬rich Lambert in 1760 and is called “Lambert’s Cosine Law”. Basically it shows how light intensity changes as the angle of the light changes. MK350S Premium cosine receiver is the blue circle; the optimized cosine and Lambert's cosine law are almost overlapped. It is more in line with international standards for illuminance measurement - JIS AA and DIN B standards and reduced measurement errors effectively. Read More

Menu

Best Sale

UPRtek What is IES TM-30-15? Introduction

United Power Research Technology Corp. is Taiwan supplier and manufacturer in Optoelectronics Industry. UPRtek has been offering our customers high quality Spectrometer, Color Meter, Spectral PAR Meter, Spectral Color Meter, Spectrum, LED Meter, Spectradiometer, LED Measurement, LED light testing since 2010. With both advanced technology and 8 years experience, UPRtek always make sure to meet each customer's demand.


Hot Products

MK350N Premium Spectrometer

MK350N Premium Spectrometer

With three measuring options. The world’s first flicker meter of 50K Hz strobe frequency...

Read More
PG100N Spectral PAR Meter

PG100N Spectral PAR Meter

Provide light quality data and spectral primitive map, optical radiation energy data for lighting...

Read More
CV600 Spectral Color Meter

CV600 Spectral Color Meter

Designed for Cinematic and Photographic. It is not only a Light meter, but also a Color...

Read More